Back to home
Engineering Catalogue · Rev. 2026

Precision engineered water control equipment.

100% automatic, self-actuating systems. Explore our robust range of valves and gates designed for zero-maintenance reliability.

Portfolio
10 products
Actuation
Self-powered
Enquiry
24 h
Dam spillway releasing massive water flow during flood conditions with turbulent water cascading downstream
01 — Amanziflow Valves

The backbone of every installation

Self-actuating control for reservoir inlets, canal offtakes and supply lines — built in corrosion-resistant materials and sized to your site conditions.

Standards
ISO 9001 · EN 1074 · AWWA C530
Reservoir Inlet Control Valve — automatic water control valve
AV-RI · RESERVOIR INLET CONTROL VALVE

Reservoir Inlet Control Valve

Controls reservoir inflow automatically from the line pressure it manages. Configured for top-entry or bottom-entry installations.

Sizes
150 NB – 400 NB
Operating head
0.5 m dynamic – 100 m static
Entry
Top-entry / bottom-entry
Material
Corrosion-resistant SS316
Used atReservoir inlets · Bulk storage · Water transfer schemes
Diaphragm Valve — automatic water control valve
AV-DM · DIAPHRAGM VALVE

Diaphragm Valve

Control valve for precise flow and closing off for irrigation dams, with manual locking device if required.

Diameters
0.15 m – 1.6 m
Head loss range
0.5 m – 60 m
Outlet
Top outlet / bottom outlet
Option
Manual locking
Used atCanal offtakes · Pressure control · Irrigation schemes
Irrigation Valve — automatic water control valve
AV-IR · IRRIGATION VALVE

Irrigation Valve

Automatically regulates flow into irrigation supply lines and holding dams, shutting off once storage is full. A new addition to the Amanziflow range — specification details to follow.

Used atIrrigation supply · Holding dams · Canal offtakes
02 — Amanziflow Gates

Built for major water schemes

Dams, rivers and canals demand equipment on a different scale. Every gate below is fabricated for site conditions and specified to integrate directly with our valve range.

Canal Regulating Gate installed at a water infrastructure site
AG-CN · CANAL REGULATING GATE

Canal Regulating Gate

A variable buoyancy tank continuously adjusts gate position while a float control valve maintains the desired flow rate, regulated against a measuring weir or flume.

Level control
Variable buoyancy tank
Flow control
Float control valve
Measurement
Weir or flume
Used atCanals · Irrigation channels · Flow regulation
Request AG-CN data sheet
Scour Gate installed at a water infrastructure site
AG-SC · SCOUR GATE

Scour Gate

Installed at the base of dams and river weirs to remove sediment. Automatic opening for floods and closing to retain storage.

Operation
Automatic, non-electro-mechanical
Flood response
Opens automatically
Drawdown
Closes at full supply level
Override
Manual, for scheduled flushing
Used atDam scour outlets · River weirs · Sediment flushing
Integration notes

Fully automatic, non-electro-mechanical operation — manual operation is available for scheduled flushing.

Request AG-SC data sheet
TOPS Spillway Gate installed at a water infrastructure site
AG-TOPS · TOPS SPILLWAY GATE

TOPS Spillway Gate

Raises the full supply level of existing or new dams by 0.5 m to 10 m. It installs on straight or curved ogee spillways without modifying the spillway crest, using a unique outward and upward motion.

FSL raise
0.5 m – 10 m
Spillway
Straight or curved ogee
Crest
No modification required
Motion
Outward and upward
Override
Manual / telemetry option
Used atDam spillways · Full supply level raising · Flood routing
Integration notes

Manual override for emergency drawdown or environmental releases; remote telemetry operation can be incorporated when required.

Request AG-TOPS data sheet
Crest Gate installed at a water infrastructure site
AG-CR · CREST GATE

Crest Gate

Automatic crest gate that maintains a constant upstream level, releasing only the surplus. Opens and closes automatically. Ideal for weirs and run-of-river schemes where storage is limited.

Typical width
2 – 10 m
Level tolerance
± 30 mm
Control
Self-actuating, hydraulic
Used atWeirs · Run-of-river intakes · Pond level control
Integration notes

Interacts with Scour gates for sediment and debris reduced weirs.

Request AG-CR data sheet
Tidal / Estuarine Gate installed at a water infrastructure site
AG-TD · TIDAL / ESTUARINE GATE

Tidal / Estuarine Gate

Prevents saline intrusion on rising tides while allowing free drainage on the ebb. Operates entirely on differential head — no actuators, no power.

Typical width
1 – 6 m
Head differential
0.2 – 4 m
Control
Differential head
Used atEstuarine outlets · Coastal drainage · Land reclamation
Integration notes

Fitted behind a diaphragm valve on the inland channel to regulate the discharge reaching the outfall.

Request AG-TD data sheet
Release Gate installed at a water infrastructure site
AG-RL · RELEASE GATE

Release Gate

A reliable fuse gate for emergency releases from extreme floods. Controls downstream release from storage, using the head of the impoundment itself to actuate.

Duty
Controlled release
Control
Self-actuating
Used atDam outlet works · Environmental releases · Downstream supply
Integration notes

Used together with main spillway gates for emergency. Controlled release in the event of an emergency manually quickly reinstated.

Request AG-RL data sheet
Dam Outlet Valve installed at a water infrastructure site
AV-DV · DAM OUTLET VALVE

Dam Outlet Valve

Automatically regulates downstream flow with varying upstream water levels.

Duty
Downstream flow control
Flows
Large flows, high energy dissipation
Control
Self-actuating
Used atControl outflows from dams · Environmental releases · Rapid draw down
Integration notes

Designed for dependable, continuous flow control. Large flows, excellent energy dissipation.

Request AV-DV data sheet
Specification support

Specify Amanziflow for your next project.

Our engineers will help you size, select and detail the right configuration for your head, flow and site conditions.

Response within one business day · No obligation